要使用SCPI指令查詢雙向直流電源輸出電流序列的步數(shù)(即總點數(shù)),核心指令為 SOURce:LIST:COUNt?,該指令返回序列中定義的總點數(shù)(步數(shù))。以下是詳細(xì)說明與操作步驟:
SOURce:LIST:COUNt?3 表示序列包含3個點)。進(jìn)入遠(yuǎn)程模式(若設(shè)備未處于遠(yuǎn)程狀態(tài)):
plaintextSYSTem:REMote
查詢序列總步數(shù):
plaintextSOURce:LIST:COUNt?
3 表示3步)。(可選)查詢當(dāng)前序列點位置:
plaintextSOURce:LIST:ADVance:COUNter? ; 返回已執(zhí)行的步數(shù)(從1開始計數(shù))
或(部分設(shè)備支持):plaintextSOURce:LIST:INDEx? ; 返回當(dāng)前序列點索引(1-based)
pythonimport pyvisarm = pyvisa.ResourceManager()power = rm.open_resource("TCPIP0::192.168.1.100::inst0::INSTR") # 替換為實際設(shè)備地址# 進(jìn)入遠(yuǎn)程模式power.write("SYSTem:REMote")# 查詢序列總步數(shù)total_steps = int(power.query("SOURce:LIST:COUNt?"))print(f"序列總步數(shù): {total_steps}")# (可選)查詢當(dāng)前步數(shù)try: current_step = int(power.query("SOURce:LIST:ADVance:COUNter?")) print(f"當(dāng)前已執(zhí)行步數(shù): {current_step}")except pyvisa.Error: print("當(dāng)前步數(shù)查詢指令不支持或未啟用序列")power.close()
SOURce:LIST:COUNt?。LIST:COUNt?(需參考具體手冊)。PROG:LIST:COUNt?,需確認(rèn)型號支持。plaintextSOURce:LIST:FUNCtion? ; 返回"ON"表示序列已激活
SOURce:LIST:COUNt? 可能返回錯誤(如 -400 參數(shù)錯誤)。此時需先啟用序列:plaintextSOURce:LIST:FUNCtion ON
通過上述方法,可可靠地查詢雙向直流電源輸出電流序列的總步數(shù),為自動化測試與監(jiān)控提供關(guān)鍵數(shù)據(jù)支持。